Search results for "Salt lake"

showing 7 items of 7 documents

Corneal thickness differences between sexes after oxybuprocaine eye drops.

2014

PURPOSE We aimed to analyze the corneal thickness (CT) values of female and male subjects before and after instillation of oxybuprocaine 0.4% anesthetic eye drops. METHODS The CT of 30 female subjects and 28 male subjects was measured using scanning-slit corneal topography (Orbscan Topography System II, Orbscan, Inc, Salt Lake City, UT). Measurements were carried out before and 3 minutes after the instillation of oxybuprocaine 0.4% eye drops. RESULTS The difference between the baseline values and those obtained after anesthesia ranged as follows: male subjects: central, -26 to +24 μm; superior, -24 to +23 μm; inferior, -19 to +20 μm; nasal, -25 to +30 μm; and temporal, -21 to +20 μm; female…

AdultMalemedicine.medical_specialtyAdolescentSalt lakeCorneaYoung AdultSex FactorsOphthalmologymedicineHumansProspective StudiesOxybuprocaineAnesthetics LocalBaseline valuesmedicine.diagnostic_testbusiness.industryCorneal TopographyOrgan SizeCorneal topographyOphthalmologyAnestheticFemaleOphthalmic SolutionsbusinessProcaineOptometrymedicine.drugOptometry and vision science : official publication of the American Academy of Optometry
researchProduct

Anatomic study of the corneal thickness of young emmetropic subjects.

2004

PURPOSE To study the corneal thickness of young emmetropic subjects. METHODS One thousand eyes of 1000 young healthy emmetropic subjects were analyzed with the Orbscan Topography System II (Orbscan, Inc, Salt Lake City, UT) from January 2001 to May 2003. The age of the subjects ranged from 20 to 30 years old (mean +/- SD = 27.12 +/- 2.86). The mean of 5 consecutive measurements of the corneal thickness in the center of the cornea and at temporal, superotemporal, inferotemporal, nasal, inferonasal, and superonasal cornea were recorded. RESULTS The corneal thickness at the following areas ranged as follows: 518 to 589 microm center; 603 to 678 microm nasal; 620 to 689 microm superonasal; 600 …

AdultMalemedicine.medical_specialtybusiness.industryEmmetropiaCorneal TopographySpherical equivalenteye diseasesSalt lakeCorneaOphthalmologymedicine.anatomical_structureReference ValuesOphthalmologyCorneamedicineHumansFemalesense organsProspective StudiesbusinessCornea
researchProduct

Quantitative anatomical differences in central corneal thickness values determined with scanning-slit corneal topography and noncontact specular micr…

2005

PURPOSE This study was designed to analyze the differences in central corneal thickness values determined with noncontact specular microscopy and scanning-slit corneal topography. The measurements were performed on the same eye. METHODS We analyzed the central corneal thickness values of 93 patients (n = 93) by means of noncontact specular microscopy (Topcon SP-2000P noncontact specular microscope, Topcon Corp., Tokyo, Japan) and scanning-slit corneal topography (Orbscan Topography System II, Orbscan Inc., Salt Lake City, UT). One experienced physician performed 3 consecutive central corneal thickness measurements with both devices. RESULTS The central corneal thickness values obtained by m…

Adultmedicine.medical_specialtyMicroscopyMaterials sciencegenetic structuresmedicine.diagnostic_testbusiness.industryCorneal TopographyReproducibility of ResultsCorneal topographySliteye diseasesSalt lakeCorneaOphthalmologyOpticsReference ValuesOphthalmologySPECULAR MICROSCOPYmedicineHumanssense organsProspective StudiesbusinessCornea
researchProduct

Orbscan Pachymetry: Differences between observers when carrying out measurements of the corneal thickness

2005

espanolObjetivo: Estudiar el espesor corneal y la variabilidad entre observadores de las mediciones del espesor corneal empleando paquimetria Orbscan. Metodos: Analizamos el espesor corneal central y paracentral de 30 sujetos (n=30) cuya edad oscilaba entre 19 y 38 anos (media 27,27 D.E. 5,25) con el Sistema Topografico Orbscan II (Orbscan, Inc., Salt Lake City, UT, USA). La media de cinco mediciones consecutivas del espesor corneal fue obtenida por dos diferentes observadores. Los resultados obtenidos por los dos observadores se compararon. Resultados: No se encontraron diferencias significativas entre los valores medios del espesor corneal de los observadores en la cornea central (p=0,749…

Physicsmedicine.medical_specialtycorneal thicknessSalt lakeCórneaCorneaOphthalmologymedicine.anatomical_structureOrbscanCorneaOphthalmologymedicinepachymetryOrbscan iiCartographypaquimetríaespesor corneal
researchProduct

Multi-Temporal Soil Salinity Assessment at a Detailed Scale for Discriminating Halophytes Distribution

2016

A multi-temporal survey of soil salinity in a salt lake, recolonized by halophytes, was performed using electromagnetic induction (EMI) providing volume integrated values of soil apparent electrical conductivity (ECa). Inventories of plant communities were recorded according to the Braun-Blanquet method. In each of six areas monospecific with Suaeda vermiculata, Suaeda vera, Sarcocornia fruticosa, or Arthrocnemun macrostachyum, ECa was measured intensively in two seasons. Mean and range of ECa differ for each plant community. Soil was sampled in the six areas and analyzed for ion composition of the soil saturated paste extract. The electrical conductivity of the saturated paste extract (ECe…

HydrologySuaeda veraSoil salinityGeographybiologyHalophyteSoil scienceSoil propertiesPlant communityGeostatisticsScale (map)biology.organism_classificationSalt lake
researchProduct

Late postoperative opacification of MemoryLens hydrophilic acrylic intraocular lenses Case series and review

2003

Abstract Purpose: To report clinical and spectrographic analyses of 2 explanted hydrophilic acrylic intraocular lenses (IOLs). Setting: John A. Moran Eye Center, Salt Lake City, Utah, USA, and Johannes Gutenberg-University, Department of Ophthalmology, Mainz, Germany. Methods: We report 6 cases of opacification of MemoryLens ® IOLs (Ciba Vision) that occurred approximately 2 years after implantation. The anterior and posterior surfaces of the IOLs had a white, frosted appearance, and the IOLs' interior looked brown, similar to the appearance of a brunescent cataract. Two of the IOLs were explanted because of a significant decrease in visual acuity. The IOLs were sent for further clinicopath…

Malemedicine.medical_specialtyVisual acuitygenetic structuresmedicine.medical_treatmentAcrylic ResinsVision DisordersVisual AcuityIntraocular lensSalt lakeLens Implantation IntraocularDevice removalOphthalmologymedicineHumansDevice RemovalAgedAged 80 and overLenses IntraocularPhacoemulsificationElectron probe microanalysisbusiness.industryCalcinosisPhacoemulsificationeye diseasesSensory SystemsProsthesis FailureOphthalmologyIntraocular lensesCalciumFemaleSurgerysense organsBrunescent cataractmedicine.symptombusinessElectron Probe MicroanalysisJournal of Cataract & Refractive Surgery
researchProduct

Revisiting the Salt Lake City Olympic scandal: Would the outcome be different today?

2016

Many international sport organizations face bribery scandals resulting from its event bidding process. The International Olympic Committee (IOC) faced this type of scandal with the 2002 Olympic Winter Games. Two members of the Salt Lake City Organizing Committee (SLOC) faced 15 criminal charges from providing more than US$1.2 million in cash and gifts to entice IOC members to support its bid. Ultimately both SLOC members were acquitted of all charges. Can a new interpretation of the United States’ anti-bribery law, the Foreign Corrupt Practices Act (FCPA), be effective in preventing similar sport scandals? peerReviewed

lcsh:SportslahjontaCorruptionmedia_common.quotation_subjectcorruptionbriberyAdvertisinghospitalityGeneral Medicinesport marketingOutcome (game theory)Salt lakelcsh:GV557-1198.995Political economyPolitical sciencekorruptioCommon value auctionlawvieraanvaraisuusmedia_commonChoregia
researchProduct